AccuPower® STI4C-Plex Real-Time PCR Kit

The AccuPower® STI4C-Plex Real-Time PCR Kit is an in vitro diagnostic kit designed for the simultaneous detection of Candida albicans, Gardnerella vaginalis, Ureaplasma parvum and Treponema pallidum DNA in human samples such as urine and vaginal swab through real-time PCR using ExiStation™ Molecular Diagnostic System or Exicycler™ 96
Inquire
Cat. No.
STI4C-1111

Sexually Transmitted Infection (STI) is an infection that can be transferred from one person to another by means of sexual contact, including oral sex, anal sex, and sharing sex toys. Candida albicans (CA) cause common vaginal yeast infection, which 75 percent of women experience once in their lifetime. Symptoms include itching of the external genitals and pain and discomfort during urination. Gardnerella vaginalis (GV), like Candida albicans, is the most common cause of women's vaginitis, pelvic inflammatory disease and endometriosis in women. Ureaplasma can be divided into Ureaplasma urealyticum (UU) and Ureaplasma parvum (UP). Ureaplasma parvum (UP) is less pathogenic than other pathogen unlike other sexually transmitted bacteria. It can be pathogenic to both men and women, and can cause uteritis in pregnant women. Finally, Treponema pallidum (TP) is a bacterium that causes syphilis. In adults, although the mildew is a characteristic lesion, it can affect skin ulcers, paralysis and organ damage depending on the extent. In the latter part of pregnancy, pathogens can spread to the fetus and endanger the life of the fetus.Early identification and treatment results in less chance to spread disease and for some conditions may improve the outcomes of treatment.

Features and Benefits

  1. Multiplex Detection: Simultaneous detection of 8 STI pathogens with STI8A-Plex and STI8B-Plex Real-Time PCR Kit using ExiStation™ MDx System.
  2. Signature Convenience: All components for the assay are contained within a tube.
  3. Enhanced Sensitivity & Specificity: Bioneer’s proprietary HotStart technology accomplishes high sensitivity and specificity.
  4. Remarkable Stability: Vacuum-dried premix allows stable and reproducible results.
  5. High Quality: All diagnostic kits manufactured by Bioneer are under strict quality control guidelines.

Specifications

  Specimen Type Urine, vaginal swab
  Kit Contents PCR Premix, PC, IPC, NTC, DEPC D.W.
  Instrumentation ExiStation™ Universal Molecular Diagnostic System or Exicycler™ 96
  Tests 96

Performances

 STI4C_fig1

(A) Example of positive results using Positive Control.
(B) Example of negative results using No Template Control.
(C) Example of Final Results. ExiStation Manager software automatically analyzes the test results based upon the Ct (threshold cycle) value.


Ordering Information

Cat. No. Product Description
STI4C-1111 AccuPower® STI4C-Plex Real-Time PCR Kit (96 tests)


Related Products

Cat. No. MDx Diagnostic Kit
CHT-1111 AccuPower® CT Real-Time PCR Kit (96 tests)
STD2A-1211 AccuPower® CT&NG Real-Time PCR Kit (96 tests)
STI8A-1111 AccuPower® STI8a-Plex Real-Time PCR Kit (96 tests)
STI8B-1111 AccuPower® STI8B-Plex Real-Time PCR Kit (96 tests)
Cat. No. Instrument
A-2060 Exicycler™ 96 Real-Time Quantitative Thermal Block
A-2200 ExiStation™ Universal Molecular Diagnostic System
A-5050 ExiPrep™16 Dx Automated Nucleic Acid Extraction System (16 tests)
Cat. No. Nucleic Acid Extraction Kit
K-4414 ExiPrep™ Dx Bacteria Genomic DNA Kit (96 tests)

Quality Assurance

Bioneer is the holder of Quality Management System Certificates for the following standards.ISO 13485 - certificate

Contact Us

E-mail : sales@bioneer.com

Copyright© 2023 BIONEER CORPORATION. All rights reserved.