AccuPower® SARS-CoV-2 Real-Time RT-PCR Kit
The AccuPower® SARS-CoV-2 Real-Time RT-PCR Kit is a multiplex real-time RT-PCR assay that proceeds from nucleic acid extraction to amplification using the ExiPrep™ 48 Dx (A-5150) instrument for automated nucleic acid extraction and Exicycler™ 96 (A-2060-1) for real-time PCR. This kit is intended for use as an aid diagnosis the in vitro qualitative detection of SARS-CoV-2 (RdRp gene, N gene, E gene) RNA isolated from human nasopharyngeal and oropharyngeal swab, and saliva from individuals with signs and/or symptoms of respiratory viral infection. The AccuPower® SARS-CoV-2 Real-Time RT-PCR Kit is intended to be performed by healthcare professionals in laboratory conditions.
Note.
- This kit is a 3-in-1 multiplex kit targeting the E gene, RdRp gene, and N gene.
- This kit is a Premix type kit.
- For inquiries about COVID-19 diagnostic kits, please contact sales@bioneer.com.
Features
- Easy-to-Use Multiplex Kit: Detects three targets in a single tube, reducing hands-on steps.
- Convenient Premix Format: Contains all assay components in each tube, eliminating reagent preparation and mixing.
- Accurate SARS-CoV-2 Detection: Uses one target for pan-coronavirus screening (E gene) and two targets for SARS-CoV-2 confirmation (RdRp gene and N gene).
- Saliva-Validated Testing: Supports saliva as well as nasopharyngeal and oropharyngeal swabs, offering a noninvasive collection option for broader screening.
- Enhanced Sensitivity & Specificity: Achieves high sensitivity and specificity with Bioneer’s proprietary Dual-HotStart technology.
- Remarkable Stability: Provides stable and reproducible results with a vacuum-dried premix.
- High Quality: Manufactured under strict quality control guidelines (ISO 13485 & KGMP), as are all Bioneer diagnostic kits.
Performance
Clinical performance was evaluated using 164 positive and 500 negative specimens for each specimen type.| Specimen Type | Clinical Sensitivity | Clinical Specificity |
|
Nasopharyngeal and oropharyngeal swab |
100.00% |
100.00% |
|
Saliva |
100.00% |
100.00% |
- Limit of detection: 32 IU/mL for all targets(E, RdRp, N genes) in both Nasopharyngeal and oropharyngeal swab, and saliva specimens
Specifications
- Kit type: Premix type
- Target: E gene, RdRp gene, N gene
- Specimen type: Saliva, Nasopharyngeal and oropharyngeal swab
- Compatible system: ExiStation™ 48 (ExiPrep™ 48 Dx + Exicycler™ 96)
- Storage: -25°C to -15°C
Kit Components
| Component | Volume | Quantity | Number of Tests |
| NCVM2 Premix | 8 tube/strip X 12 strips | 1 pack | 96 tests/kit |
| PCa) | 15 µL/tube (0.2 mL 8-tube strip, Natural) | 1 strip | 1 test/tube |
| NTCb) | 15 µL/tube (0.2 mL 8-tube strip, Yellow) | 1 strip | 1 test/tube |
| SL buffer | 1,800 µL/tube (2.0 mL clear screw-cap tube) | 8 tubes | 1 test/tube |
| Optical Sealing Film | - | 1 ea | - |
| Quick Manual | - | 1 ea | - |
a) Positive Control, b) No Template Control
Ordering Information
| Cat. No. | Product Description |
| NCVM2-1111 | AccuPower® SARS-CoV-2 Real-Time RT-PCR Kit (96 tests) |
Related Products
| Cat. No. | Instrument |
| A-5150 | ExiPrep™ 48 Dx |
| A-2060-1 | Exicycler™ 96 |
| A-7040 | ExiSpin™ |
| Cat. No. | Nucleic Acid Extraction Kit |
| K-4571 | ExiPrep™ 48 Viral DNA/RNA Kit |
| KA-4505 | ExiPrep™ 48 Sample Loading Tube |
| K-4575 | ExiPrep™ 48 Fast Viral RNA Kit |
| K-4172 | Saliva collection Kit |
Contact Us
Please contact order and marketing request via e-mail.
E-mail : sales@bioneer.com
v1.0 / 2020-04-28